Installation; Mounting Method - Takex PIR-T40NAM Instruction Manual

Triple mirror passive sensor, vertical curtain protection
Table of Contents

Advertisement

5

INSTALLATION

The mounting height and adjustable detection distance depend on the operation mode. Carefully check the operation mode and
detection area setting before installation and area setting.
Use the unit with the correct operation mode setting. Select operation mode to use and perform the setting correctly.
This unit can be operated from ① to ④ modes, as follows.
●Normal operation modes
Normal operation mode reduces the false detection caused by small animals
and lost detection of humans. There are three position modes according to
mounting height "Low" "Middle" and "High".
①Low position mode :
When the sensor is mounted between a height of 6.6' to 8.3' (2.0 to 2.5m).
②Middle position mode :
When the sensor is mounted between a height of 8.3' to 11.5' (2.5 to 3.5m).
③High position mode :
When the sensor is mounted between a height of 11.5' to 13' (3.5 to 4.0m).
When the mounting height is 8.3'(2.5m), Low or Middle position is selectable.
When the mounting height is 11.5'(3.5m), Middle or High position is selectable.
●Specialized operation mode
This is operation setting to extremely reduce the lost detection in detection area.
④High density mode
Mounting height is 6.6'' to 20' (2.0 to 6.0m).
The mode setting can be selected from above ①〜④ modes. (Refer to "7 FUNCTION")

■Mounting method

1. Loosen the cover locking screw
and remove the cover unit.
2. Insert the wire through the grommet in the wiring
hole at the bottom of the sensor unit. Break the
mounting hole knockout of the sensor unit and
mount using the supplied tapping screws.
* Adjust mounting height of the sensor using the
center of the sensor unit as a guide.
Insert the wires for power input and alarm
output through the wiring hole on the left,
and for tamper output and starting output on
the right. Be careful not to cross the wires.
* For open wiring, break the knockout on the rear
side of the sensor unit, and pull the wire
through it.
3. Connect the wires to each terminal.
(Refer to "6 WIRING")
When mounting on the pole
[Use the pole attachment]
Pole diameter
Dia 1.5" to1.8"
(φ 38 to 45mm)
Pole
attachment
BP-32
When mounting the unit on a vertical pole, use the pole attachment
(sold separately). The unit can be mounted on poles of Dia 1.5" to 1.8"
(φ38 to φ45mm) and Dia 1.6" to 5.5" (φ40 to φ140mm).
* Mount the sensor so that its mounting surface is positioned vertically.
Low position mode
Middle position mode
High position mode
High density mode 
Center of
the sensor
Wiring
Wiring
(Power, Alarm)
(Tamper, External)
When mounting on the ceiling or under eaves
[Use the ceiling attachment]
Pole diameter
Dia 1.6" to 5.5"
(φ 40 to 140mm)
Pole
attachment
BP-02
Ceiling
attachment
KP-32
When mounting on the ceiling or under eaves,
use the ceiling attachment (sold separately).
* Mount the sensor so that its mounting
surface is positioned vertically.
Operation mode
Installation height
6.6  to 8.3  (2.0 to 2.5m)
8.3  to 11.5  (2.5 to 3.5m)
11.5  to 13  (3.5 to 4.0m)
6.6  to 20  (2.0 to 6.0m)
* When the unit operates with anti-masking
function ON, mount it at least 1ft. (30cm)
away from any adjoining wall / surface to
avoid unexpected reflection.
4. Set the detection area and functions according to
the installation site.
(Refer to "4 DETECTION AREA", "7 FUNCTION",
and "8 ADJUSTMENT OF DETECTION")
5. Replace the cover unit,
and fix it by
tightening the cover
locking screws.
6. When the detection area and functions settings
are completed, go to section "9 OPERATION
CHECK".
Pole 
attachment
BP-32
Detection distance
135  (40m)
115  (35m)
100  (30m)
150  (45m)
1ft
(30cm)
* When installing
outdoors, mount the
anti bird spike above
the cover unit. Turn
the anti bird spike and
tighten it.
Pole 
attachment
BP-32
When using the pole
attachment BP-32 (sold
separately), break the
knockout on the rear
side of the sensor unit,
and attach it.