OPTICAL AXIS ADJUSTMENT USING THE ALIGNMENT MECHANISM

1
Move the swivel base and swing arm so that the opposite device is roughly aligned with the view finder.
Or
Horizontal angle adjustment
2
Look closely through the view finder, and adjust the position so that the sensor of the opposite device is visible at the center of the ring
using the horizontal and vertical angle fine adjustment screws.
Or
Horizontal angle fine adjustment
Look through the view finder from a distance, and readjust so that the sensor of the opposite device is visible at the center of the ring
3
using the horizontal and vertical angle fine adjustment screws.
Or
Horizontal angle fine adjustment
4
Turn on the power to the transmitter and receiver, check that the LEDs of both the transmitter and receiver are lit.
Transmitter
If the LED of the receiver indicates as follows, take an appropriate measure according to the following description.
(1) The light enters the receiver, but the light reception
(1) Different channels are set for the transmitter and
(2) The photoelectric beams are interfered
(1) The light does not enter the receiver at all
Vertical angle adjustment
Vertical angle adjustment
Vertical angle adjustment
Lit
Description of the Display
level is insufficient
(The optical axis is misaligned)
receiver
(The optical axis is not adjusted correctly)
Receiver
5
(1) Go to step
(1) Set the same channel for the transmitter and
receiver
(2) Change to a channel that is not influenced by
other factors
Go back to step
Lit
Remedy
and fine adjust the optical axis
1
and adjust the optical axis again

Advertisement