Possible Problem
The hood is not
venting out properly.
Filter is vibrating.
RF Remote control
does not work.
Trapeze Use, Care, and Installation Guide
Possible Cause
Using the wrong size of ducting.
The hood might be hanging to
high from the cook top.
The wind from the opened
windows or opened doors in the
surrounding area are affecting
the ventilation of the hood.
Blockage in the duct opening or
ductwork.
There are too many turns within
the ducting.
Filter is loose.
Battery is dead.
Poor communication with the
hood.
RF Remote lost communication
with the hood.
Troubleshooting
Solutions
Change the ducting to at least 6" or
higher for the internal blower and 8" or
higher for the external blower.
Adjust the distance between the cooktop
and the bottom of the hood within 24"
and 36" range.
Close all the windows and doors to
eliminate the outside wind flow.
Remove all the blocking from the duct
work or duct opening.
Limit number of turns and/or increase
duct size.
Adjust or change the filter.
Replace battery with type A23 12v.
Remote control must be within 15 ft of
hood.
Reset hood and remote by switching
power off at the circuit breaker for 5
minutes. Place remote on counter top
near the hood and switch the circuit
breaker back on.