PrecisionFlo XL TouchScreen Interface
Calibration – Pressure Screen
Fig. 50
Table 33—Calibration Pressure Screen Values
Description
*Inlet Voltage at 0 Pressure
*Outlet Voltage at 0 Pressure
[Inlet Pressure at 5 V
[Outlet Pressure at 5 V
Kp
Ki
Actual Inlet Pressure
Actual Outlet Pressure
*
These values can be adjusted to calibrate the inlet and outlet regulator pressure transducers.
[ These pressures should match the pressure range switch positions on the transducer amplifier card in the fluid
plate junction box (see fig. 77).
72
309374
Possible Values
0.0–2.0 V
0.0–2.0 V
0.0–344.83 bar/0.0–5000 PSI
0.0–344.83 bar/0.0–5000 PSI
0.0–999.0
0.0–999.0

Advertisement