Calibration—Pressure Screen
Dispense Mode: Manual
Inlet Voltage at 0 psi
Outlet Voltage at 0 psi
Inlet Press at 5 V
Outlet Press at 5 V
* Kp
* Ki
Actual Inlet Press
Actual Outlet Press
Pressure
Setup 1
No Active Alarms
Fig. 28
Table 18—Pressure Screen Values
Description
Inlet Voltage at 0 psi (0 bar)
Outlet Voltage at 0 psi (0 bar)
Inlet Pressure at 5 V
Outlet Pressure at 5 V
*Kp
*Ki
Actual Inlet Pressure
Actual Outlet Pressure
* Set by the AutoTune process
[ These values can be adjusted to calibrate the pressure transducers on the inlet and outlet of the fluid control
regulator
[[ These pressures should match the pressure range switch positions on the transducer amplifier card in the fluid
plate junction box (see fig. 77).
NOTE: To calibrate pressure, push the Gun 1 or Gun 2 button on the keypad while on this screen.
Reg 1
X.XX
X.XX
XXXX
XXXX
XXX
XXX
XXXX
XXXX
Flow Rate
Setup 2
Calibration
Possible Values
0–5.00 V [
0–5.00 V [
0–5000 psi [[
0–5000 psi [[
0–999
0–999
0–5000 psi
0–5000 psi
Reg 2
X.XX
V
X.XX
V
XXXX
psi
XXXX
psi
XXX
XXX
XXXX
psi
XXXX
psi
Faults
PrecisionFlo XL EasyKey Interface
Default Value
1.00
1.00
3500
3500
160
8
N/A
N/A
309374
53