Configuring Software
Other System Variables
After the calibration and robot path programming is complete and the desired bead profiles have been
achieved, verify that the following variables are set.
Table 7—PrecisionFlo XL System Variables
Screen
Variable / Preset
Setup2 – Styles
Volume
Setup1 – Modes
Tolerance
Faults – Level
Set the User configurable faults to Alarms or Warnings. More information on the faults
can be found in the User Interface section.
An Alarm will cause the fault signal to activate and the system ready signal to drop out.
This is something considered by the user to be a major fault, one which causes the
system to stop dispensing.
A Warning will cause the fault signal to activate and the system ready to stay on. This
is something considered by the user to be a minor fault, one which will warn the user
but will continue dispensing even if the bead profile is degraded.
36
309374
Values
Comments
0 – 9999 cc, 100 cc
Set the volume set point for each of the 32
styles being used.
0 – 99.9%, 10%
Set the volume tolerance for each of the 32
styles being used.