PrecisionFlo XL TouchScreen Interface
Config – Temperature Screen
Fig. 44
Table 28—Config Temperature Screen Values
Description
Zones 1 – 4
PID—Close Window
*The PID field will display "Autotune" if there is an Auto-
tune in progress. After completion of the Autotune pro-
cess, the field will change to "Done."
Set Point
Tolerance
Temperature
Temperature Units
*If you select AutoTune for any zone and press Enter, the AutoTune process for that zone begins. The control will
heat and monitor that device to automaticall determine the correct PID values. This process takes from 5 to 40 min-
utes and should be started from ambient temperature. When complete, the field displays "Done"
NOTES:
D If set points are entered in Celsius and the readout is later changed to Fahrenheit, the set points are automati-
cally converted.
D If "Temperature Conditioning" was selected on int Setup 1, Config screen, default PID values are automatically
set for zone 1. If these values are changed, they will revert back to the default values at the next power up.
66
309374
Possible Values
On/Off
Autotune/Dispense Valve/Fluid Plate/Hose/Regulator/
Done
Setting a device sets the proper PID values for that de-
vice.
60.0–176.0_F/x.x–x.x _C
2.0–50.0_F/x.x–x.x _C
Displays actual temperature reading
Fehrenheit/Celsius