Output Display
Specifications
NOTE:
Reports
Power and Utility
Requirements
Environmental
Requirements
Physical
Characteristics
Enclosure Rating
Approvals
Connectors
Options
Remote Set Point
Input Option - Basic
Function
RS422/485 (Serial
Port Option) - Basic
Function
2-2
•
Liquid Crystal Display (LCD) - 80 characters
•
Display Format: 4 line x 20 character full ASCII (5 x 7 dot matrix)
•
Display Increments: 1,2,5,10,20,50,100,200,500 counts selectable
by keypad. Corresponding weight is dependent on decimal point
location.
Only the weight display increments are effected by graduations
•
Automatic Batch Reports
•
Print Screen Available
•
Two Sigma
•
120 VAC (47-63 Hz) Standard from factory.
•
240 VAC (47-63 Hz) (Optional) Installed at factory with power and
relay modifications.
•
Operating Temperature Range: -10 to 50 C (14 to 122 F)
•
Storage Temperature Range: -20 to 85 C (-4 to 185 F)
•
Temperature Coefficient: Less than 0.005% of full scale per degree
C for zero and span.
•
Overall Size - 7"W x 4.88"H x 10.04"L
•
Weight: 6 pounds (2.72 Kilograms)
•
NEMA 4 & 4x Seal when placed in a NEMA 4 & 4X Enclosure.
•
UL Certification
•
CSA Certification
•
Factory Mutual (FM) Approval
•
Relays: Phoenix 12 pin connector
•
RS-232: Phoenix 6 pin connector (Standard)
•
Alarm Relays: Phoenix 6 pin connectors
•
Load Sensors: Phoenix 8 pin connectors
1. Reads analog input signals from a master controller, Program-
mable Logic Controller (PLC), or from a main ingredient flow
meter device.
2. Changes the rate of flow set point to proportionally track the
master controller's flow rate.
3. Changes the rate of flow set point to a new fixed rate, down-
loaded by the PLC via analog signal, if the input trigger is
pulsed
4. Interface to the 2160 Rate Controller - Selectable 0-20 mA, 4-
20 mA, 0-5 VDC, 0-10 VDC analog input signal.
1. Converts the Standard Serial Port from RS 232 to RS 422/485
signals.