Power input
After connecting cables to the other ports, connect a cable from the 120 VAC or 240 VAC,
50‑60 Hz mains power source to this IEC plug.
Rear Panel
100/240V ~ 12/10A MAX
BREAKER
KER
R
50-60Hz
50-
0-60
0-60
0-60
0-60
0-60
0-60
0-60
0-60
0-60
0-60
0-60
0-60
-60
-6
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-6
-60
60
60
H
H z
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
Connect to
mains power.
Figure 6.
Power Input
Circuit breaker
The rear panel features a 12 A rated circuit breaker. When a fault condition
occurs, the breaker is triggered, which stops power output. Any attempt to
control the AC outputs is ignored while the fault condition is present. The front
panel Breaker LED lights. This condition can be monitored and the system can
be configured (using available commands) to send an alert e‑mail or perform
some other action. After you correct the cause of the overcurrent condition,
Breaker
press the
button to manually reset the circuit breaker and turn off the LED.
The AC power ports remain off until they are manually turned on via software (GC or GS
program), via controls in the embedded webpage, or by using SIS commands over an SSH
connection. This prevents inadvertent damage to equipment when the user resets the
switch before the condition is cleared.
Power output — switched AC power output
Switched AC power output ports — The IPL EXP PDU4H features switched, monitored
AC power output ports to provide power to various AV products.
Power output can be toggled on and off using manual contact closure control, SIS
commands, configuration or programming commands, or controls in the embedded
web page.
These ports are monitored continuously for total combined current draw (aggregate
current sensing). They remain on as long as there is no overload condition and as long
as they are set to "On".
The system can be set up to monitor the circuit breaker. The AC current value and
circuit breaker status are shown in the IPL EXP PDU4H embedded web page. The
system can be configured to alert users in the event of a power fault interruption.
The IPL EXP PDU4H provides a maximum output of 12 A at 120 VAC or
10 A at 240 VAC, combined, for all the AC output ports together.
1
1
1
Power Input
• Connect to
• Front panel LED (
120 or 240 VAC,
blinks during boot-up
50-60 Hz.
and remains lit when
the IPL EXP receives
power.
IPL EXP PDU4H • Hardware Features and Installation
Front Panel
)
R
Power and
Reset LED
BREAKER
15

Advertisement

Table of Contents
loading

Table of Contents