Appendix 1: DeviceNet Explicit Messages
A-1-2
Explicit Messages
Reading General Status
Explicit
Read/
message
write
General
Read Reads the
Status Read
specified slave's
status flags (8 bits)
Setting and Monitoring the Unit Conduction Time
Explicit
Read/
message
write
Unit
Read Reads the set
Maintenance
value for the Unit
Set Value
Conduction Time
(unit: 0.1 h).
Write
Writes the set
value
for the Unit
Conduction
Time (unit: 0.1 h).
Unit
Read Reads the present
Maintenance
value for the Unit
Present
Conduction
Value
Time (unit: 0.1 h).
Unit
Read Reads the monitor
Maintenance
status of Unit
Flag
Conduction Time.
A-4
Function
Service
Class
code
0E hex 95 hex 01 hex
Function
Service
Class
Code
0E hex 95 hex 01 hex
10 hex 95 hex 01 hex
0E hex 95 hex 01 hex
0E hex 95 hex 01 hex
Command
Instance
Attribute
ID
ID
ID
65 hex
Command
Instance
Attribute
ID
ID
ID
73 hex
4 bytes
0000 0000 to
73 hex
FFFF FFFF hex
(0 to
4,294,967,295)
71 hex
72 hex
Response
Data size
1 byte
Response
Data size
4 bytes
0000 0000 to FFFF
FFFF hex
(0 to
4,294,967,295)
4 bytes
0000 0000 to FFFF
FFFF hex
(0 to
4,294,967,295)
1 byte
00 hex: Within
range
01 hex: Over range
(over the monitor
value)