Omron DeviceNet DST1 Series Operation Manual page 103

Safety i/o terminals
Hide thumbs Also See for DeviceNet DST1 Series:
Table of Contents

Advertisement

Explicit
Read/
message
write
Output Total
Reset Resets the total ON
ON Time or
time or number of
Contact
contact operations
Operation
for time output (1 to
Counter
8) specified by the
Reset
instance ID.
Output
Read
Reads the set value
Monitor
for the total ON time
Status for
or number of
Total ON
contact operations
Time or
of the output (1 to 8)
Contact
specified by the
Operation
instance ID.
Counter Read
Safety Output
Read
Reads the cause for
Cause of
the normal flag (1 to
Error
8) specified by the
Information
Instance ID turning
Read
OFF.
Function
Service
Code
05 hex
0E hex
0E hex
Appendix 1: DeviceNet Explicit Messages
Command
Class
Instance
Attribute
ID
ID
ID
3B
01 to 08
66 hex
hex
hex
3B
01 to 08
67 hex
hex
hex
3B
01 to 08
6E hex
hex
hex
Response
Data size
1 byte
00 hex: Within
range
01 hex: Over
range (over the
monitor value)
0: No error
01 hex: Con-
figuration invalid
02 hex:
Overcurrent
detected
03 hex:
Short-circuit
detected
04 hex:
Stuck-at-high
detected
05 hex: Error in
the other dual
channel output
06 hex: Internal
relay relevant
circuit error
07 hex: Relay
failure
08 hex: Dual
channel violation
09 hex: Cross
connection
detected
A-7