If the system-level diagnostics
tests...
Were completed without any
failures
With two nodes in the cluster
With more than two nodes in the
cluster
In a two-node MetroCluster
configuration
In a stand-alone configuration
Then...
a. Clear the status logs:
b. Verify that the log was cleared:
The following default response is displayed:
SLDIAG: No log messages are present.
c. Exit Maintenance mode on both controllers:
The system displays the LOADER prompt.
You must exit Maintenance mode on both
controllers before proceeding any further.
d. Enter the following command on both controllers at the LOADER
prompt:
bye
e. Return the node to normal operation:
Issue these commands:
-configured true
node::> storage failover modify -node node0
-enabled true
Issue this
command:node::> storage failover modify
-node node0 -enabled true
Proceed to the next step.
The MetroCluster switchback procedure is done in the next task in the
replacement process.
You have no further steps in this particular task.
You have completed system-level diagnostics.
sldiag device clearstatus
sldiag device status
halt
node::> cluster ha modify
659