The following table lists the holding registers for the "C" Group Intelligent Input Functions.
Func.
Code
C001 Terminal [1] function
C201
Terminal [1] function,
2nd motor
C002 Terminal [2] function
C202
Terminal [2] function,
2nd motor
C003 Terminal [3] function
C203
Terminal [3] function,
2nd motor
C004 Terminal [4] function
C204
Terminal [4] function,
2nd motor
C005 Terminal [5] function
C205
Terminal [5] function,
2nd motor
C011
Terminal [1] active state R/W
C012
Terminal [2] active state R/W
C013
Terminal [3] active state R/W
C014
Terminal [4] active state R/W
C015
Terminal [5] active state R/W
C021
Terminal [11] function
C026 Alarm relay terminal
function
C028 [AM] signal selection
C031
Terminal [11] active
state
C036
Alarm relay active state
C038
Output mode of low load
detection signal
C039
Low load detection level
C041 Overload level setting
C241
Overload level setting,
2nd motor
C042
Frequency arrival
setting for acceleration
C043
Frequency arrival
setting for deceleration
List of Holding Registers
Name
R/W
R/W
R/W
R/W
R/W
R/W
See "Input Terminal Configuration"
R/W
R/W
R/W
R/W
R/W
Select logic conversion, two option
codes:
00 normally open [NO]
01 normally closed [NC]
R/W
R/W
R/W Two available functions:
00 motor speed
01 motor current
R/W Select logic conversion:
00 normally open [NO]
01 normally closed [NC]
R/W Select logic conversion:
00 normally open [NO]
01 normally closed [NC]
R/W Three option codes:
00 Disabled
01 During acceleration,
02 During constant speed only
R/W Set the level of low load detection,
range is 0.0 to 2.0*rated current
R/W
Sets the overload signal level
between 0% and 200% (from 0 to two
time the rated current of the
R/W
inverter)
R/W Sets the frequency arrival setting
threshold for the output frequency
during acceleration,
range is 0.0 to 400.0 Hz
R/W Sets the frequency arrival setting
threshold for the output frequency
during deceleration,
range is 0.0 to 400.0 Hz
Description
on page 3-49
See "Output Terminal
Configuration" on page 3-54
deceleration and constant speed
Network Data
Reg.
Range
Res.
1103h
0, 1, 2, 3,
4, 5, 6, 7,
1532h
8, 9, 11,
12, 13,
1104h
15, 16,
1533h
18, 19,
20, 21,
1105h
22, 23,
1534h
24, 27,
28, 29,
1106h
31, 50,
51, 52,
1535h
53, 64,
255
1107h
1536h
110Bh
0, 1
110Ch
0, 1
110Dh
0, 1
110Eh
0, 1
110Fh
0, 1
1114h
0, 1, 2, 3,
4, 5, 6, 7,
1119h
8, 9, 10,
43
111Bh
0, 1
111Dh
0, 1
1122h
0, 1
1178h
0, 1, 2
1179h
0 to
0.01%
20000
1124h
0 to
0.01%
20000
153Ah
1126h 0 to 4000
0.1 Hz
*1
1128h 0 to 4000 0.1 Hz