Accel/Decel
Standard acceleration and deceleration is
linear. The inverter CPU can also
calculate an S-curve acceleration or
deceleration curve as shown. This profile
is
useful
for
characteristics in particular applications.
Curve settings for acceleration and
deceleration are independently selected.
To enable the S-curve, use function A097
(acceleration) and A098 (deceleration).
Func.
Name /
Code
SRW Display
A097
Acceleration curve selection
ACC LINE
A098
Deceleration curve selection
DEC LINE
favoring
the
load
"A" Function
Description
Set the characteristic curve of
Acc1 and Acc2, two options:
00 linear
L
01 S-curve
Set the characteristic curve of
Dec1 and Dec2, two options:
00 linear
L
01 S-curve
Output
frequency
Accel. curve selection
Target
freq.
S-curve
A097 = 01
A097 = 00
0
Acceleration period
Run
Mode
Edit
3 − 27
3 27
Linear
t
Defaults
-FE
-FU
Units
(EU)
(USA)
00
00
00
00