4 16
Set Second Motor, Special Set
If you assign the [SET] function to an intelligent input terminal, you can select between
two sets of motor parameters. The second parameters store an alternate set of motor
characteristics. When the terminal [SET] is turned ON, the inverter will use the second
set of parameters to generate the frequency output to the motor. When changing the
state of the [SET] input terminal, the change will not take effect until the inverter is
stopped. Special Set [SP-SET] is for changing the second motor parameters without
stopping the motor. However the changeable parameters are limited.
When you turn ON the [SET] input, the inverter operates per the second set of
parameters. When the terminal is turned OFF, the output function returns to the
original settings (first set of motor parameters). Refer to
Multiple Motors" on page 4–58
Parameters
F002/F202
F003/F203
A001/A201
A002/A202
A003/A203
A004/A204
A020/A220
A041/A241
A042/A242
A043/A243
A044/A244
A045/A245
A061/A261
A062/A262
A092/A292
Option
Terminal
Code
Symbol
08
SET
53
SP-SET
Valid for inputs:
Required settings
Notes:
If the terminal state is changed while the
inverter is running, the inverter continues using
the current set of parameters until the inverter
is stopped.
for details.
SET
SP-SET
-
-
-
-
-
-
-
Function Name
State
Set (select) 2nd
Motor data
Set 2nd motor data
OFF
Special SET
C001~C005
(none)
Parameters
SET
A093/A293
A094/A294
A095/A295
A096/A296
b012/b212
b013/b213
b021/b221
b022/b222
b023/b223
b028/b228
C001~C005/
C201~C205
C041/C241
H003/H203
H004/H204
H006/H206
ON
causes the inverter to use the 2nd set of motor
parameters for generating the frequency output to
motor
causes the inverter to use the 1st (main) set of
motor parameters for generating the frequency
output to motor
Example (requires input configuration—see
page
3–49):
5
See I/O specs on
page 4–6.
"Configuring the Inverter for
SP-SET
-
-
-
-
-
-
-
-
-
-
-
Description
SET / SP-SET
4
3
2
1
L PCS P24

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

X200 series

Table of Contents