Hitachi CONVENTION 14 Instruction Manual page 97

Single-phase input 200v class; three-phase input 200v class; three-phase input 400v class
Table of Contents

Advertisement

3 − 14
3 14
Func.
Code
A005
[AT] selection
AT-Slct
A011
O-L input active range start
frequency
O-EXS
A012
O-L input active range end
frequency
O-EXE
A013
O-L input active range start
voltage
O-EX%S
A014
O-L input active range end
voltage
O-EX%E
A015
O-L input start frequency
enable
O-LVL
A016
External frequency filter time
constant
F-SAMP
A016: External Frequency Filter Time Constant – This filter smoothes the analog
input signal for the inverter's output frequency reference. A016 set the filter range
from n=1 to 16. This is a simple moving average calculation, where n (number of
samples used) can be selected.
"A" Function
Name /
SRW Display
Five options; select codes:
02...Select between [O] and
03...Select between [OI] and
04...Only [O] input active
05...Only [OI] input active
O/VR
The output frequency
corresponding to the analog input
range starting point,
range is 0.0 to 400.0
0000.0Hz
The output frequency
corresponding to the analog input
range ending point,
range is 0.0 to 400.0
0000.0Hz
The starting point (offset) for the
active analog input range,
range is 0. to 100.
00000%
The ending point (offset) for the
active analog input range,
range is 0. to 100.
00000%
Two options; select codes:
00 Use offset (A011 value)
0Hz
01 Use 0Hz
Range n = 1 to 17, where n =
number of samples for avg.
00008
Description
keypad potentiometer at [AT]
integrated POT at [AT]
Defaults
Run
Mode
-FE
-FU
Units
Edit
(EU)
(USA)
02
02
0.0
0.0
Hz
0.0
0.0
Hz
0.
0.
%
100.
100.
%
01
01
8.
8.
Sam-
ples

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

X200 series

Table of Contents