Restoring Factory Default Settings

You can restore all inverter parameters to the original factory (default) settings for the
intended country of use. After initializing the inverter, use the powerup test in Chapter
2 to get the motor running again. To initialize the inverter, follow the steps below.
No.
1
Use the
navigate to the "B" Group.
2
Press the
3
Press and hold the
4
Press the
5
Confirm the country code is correct. Do not change it unless you are absolutely sure
the power input voltage range and frequency matches the country code setting.
To change the country code, press
6
Press the
7
Press the
8
Press the
9
Press the
10
Press the
11
Press and hold the
STOP
RESET
12
When your country code appears in
the display, release all the keys.
13
Initialization is complete
NOTE:
and use the inverter's front keypad.
Action
FUNC
1
,
, and
2
FUNC
key.
1
key until
FUNC
key.
FUNC
key.
key.
2
FUNC
key.
key.
1
STR
key.
FUNC
,
keys. Do not release yet.
Initialization cannot be performed with a remote operator panel. Disconnect the dovice
Display
"B" Group selected
keys to
b---
First "B" parameter selected.
b001
Country code for initialization
b085
selected
00=Japan, 01=Europe
02
02=USA
1
or
2
to set,
Country code for initialization
b085
selected
Initialization function selected
b084
00=initialization disabled, clear
00
trip history only
01=initialization enabled
01
Initialization now enable to
b084
restore all defaults
First part of special key sequence
and
2
b084
Default parameter country code
EU
shown during initialization
USA
process (left-most char displays
JP
alternating pattern)
Function code for output
d001
frequency monitor shown
Func./Parameter