Restoring Factory Default Settings - Hitachi wj200 series Quick Reference Manual

Hide thumbs Also See for wj200 series:
Table of Contents

Advertisement

Other indication
Error
Code
Rotating
Blinking

Restoring Factory Default Settings

You can restore all inverter parameters to the original factory (default) settings according to
area of use. After initializing the inverter, use the powerup test (please refer to Chapter 2 in
the Instruction Manual) to get the motor running again. If operation mode (std. or high
frequency) mode is changed, inverter must be initialized to activate new mode. To initialize
the inverter, follow the steps below.
(1) Select initialization mode in b084.
(2) If b084=02,
(3) If b084=02,
01
in b180.
(4) Set
(5) Initialization is started, and is completed with
* Please change
B 0 3 7
(Function code display restriction), in case some parameters cannot be displayed.
Name
Reset
Undervoltage
Waiting to restart
Restricted operation
command
Trip history initializing
No data
(Trip monitor)
Communication error
Auto-tuning
completed
Auto-tuning error
03
or 04, select initialization target data in b094.
03
or 04, select country code in b085.
from"0 4
(Basic display)" to
RS input is ON or STOP/RESET key is pressed.
If input voltage is under the allowed level, inverter shuts
off output and waits with this indication.
This indication is displayed after tripping before
restarting.
Commanded RUN direction is restricted in b035.
Trip history is being initialized.
No trip/waning data exists.
Communication between inverter and digital operator
fails.
Auto-tuning is completed properly.
Auto-tuning fails.
d001
displayed.
"0 0
(Full display)" in parameter
101
Descriptions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents