2 − 34
2 34
Monitoring Parameters with the Display
After using the keypad for parameter editing, it's a
good idea to switch the inverter from Program Mode to
Monitor Mode. The PRG LED will be OFF, and the
Hertz or Ampere LED indicates the display units.
For the powerup test, monitor the motor speed
indirectly by viewing the inverter's output frequency.
output frequency
The
frequency
frequency
functions are in the "D" list, located near the top left of the
page
2-26.
Output frequency (speed) monitor – Resuming keypad operation from the previous table,
follow the steps below. Or instead, you can simply power cycle the inverter, which
automatically sets the display to D001 (output frequency value).
(Starting point)
Press the
Press the
Press the
When the inverter displays a monitor value, the PRG LED is OFF. This confirms the
inverter is not in programming mode, even while you are selecting the particular
monitoring parameter. The display shows the current speed (is zero at this point). The
Hz LED will be ON, indicating the display units. For current, the Amperes LED will be
ON.
Running the Motor
If you have programmed all the parameters up to this point, you're ready to run the
motor! First, review this checklist:
1. Verify the power LED is ON. If not, check the power connections.
2. Verify the Potentiometer Enable LED is ON. If it is OFF, check the A001 setting.
3. Verify the Run Key Enable LED is ON. If it is OFF, check the A002 setting.
4. Verify the PRG LED is OFF. If it is ON, review the instructions above.
5. Make sure the motor is disconnected from any mechanical load.
6. Turn the potentiometer to the minimum position (completely counter clock-wise).
7. Now, press the RUN key on the keypad. The RUN LED will turn ON.
8. Slowly increase the potentiometer setting in clockwise fashion. The motor should
start turning.
9. Press the STOP key to stop the motor rotation.
must not be confused with
(50/60 Hz) of the motor, or the
(switching frequency of the inverter, in the kHz range). The monitoring
Action
FUNC
key.
1
key.
FUNC
key.
RUN
FUNC
base
carrier
"Keypad Navigation Map"on
Display
Func./Parameter
H004
Motor poles parameter
H- - -
"H" Group selected
d001
Output frequency selected
0.0
Output frequency displayed
POWER
Hz
ALARM
A
RUN
STOP
RESET
PRG
STR
2
1