Hitachi CP-X200 Instruction Manual page 29

X200 series
Hide thumbs Also See for CP-X200:
Table of Contents

Advertisement

1 − 8
1 8
X200 inverters,
400V models
Applicable motor size *2
Rated capacity
(kVA)
Rated input voltage *6
Integrated EMC
filter
Rated input current (A)
Rated output voltage *3
Rated output current (A)
Efficiency at 100% rated output
Watt loss
(fc=3kHz)
Approximate (W)
Starting torque *7
Braking
Weight
Item
EU version
USA version
kW
HP
380V
480V
EU version
USA version
at 70% output
at 100% output
Dynamic braking,
approx. % torque
(short
time
stop
from 50/60Hz) *8
DC braking
EU version
Kg
(-HFEF)
lb
USA version
Kg
(-HFU)
lb
400V class Specifications
004HFEF
007HFEF
004HFU
007HFU
0.4
0.75
1/2
1
0.9
1.6
1.2
2.0
3-phase: 380V-15% to 480V 10%, 50/60Hz 5%
SFE series : EN61800-3 category C2 filter
2.0
3.3
3-phase: 380 to 480V (proportional to input voltage)
1.5
2.5
93.8%
94.9%
20
29
25
38
50%:
Capacitive feedback type, dynamic braking unit and braking
resistor optional, individually installed
Variable operating frequency, time, and braking force
1.5
2.3
3.31
5.08
1.4
2.2
3.09
4.86
015HFEF
015HFU
1.5
2
2.5
3.1
5.0
3.8
96.4%
40
54
100% at 6Hz
60Hz
2.4
5.30
2.3
5.08
022HFEF
022HFU
2.2
3
3.6
4.5
7.0
5.5
96.9%
49
68
20%:
60Hz
2.4
5.30
2.3
5.08

Advertisement