Terminal Dimensions and Torque Specs
The terminal screw dimensions for all X200 inverters are listed in table below. This
information is useful in sizing spade lug or ring lug connectors for wire terminations.
WARNING: Fasten the screws with the specified fastening torque in the table below.
Check for any loosening of screws. Otherwise, there is the danger of fire.
Connector
Power Terminals
(Top side)
Power Terminals
(Bottom side)
Control Signal
Alarm Signal
When connecting wiring, use the tightening torque listed in the following table to safely
attach wiring to the connectors.
Screw
Tightening Torque
M2
0.2N m (max. 0.25 N m)
M3
0.5N m (max. 0.6 N m)
Wire the Inverter Input to a Supply
Step 6: In this step, you will connect wiring to the input of the inverter. First, you must
6
determine whether the inverter model you have required three-phase power only, or
single-phase power only. All models have the same power connection terminals [R/L1],
[S/L2], and [T/L3]. So you must refer to the specifications label (on the side of the
inverter) for the acceptable power source types! For inverters that can accept single-
phase power and are connected that way, terminal [S/L2] will remain unconnected.
The wiring example to the right shows an X200 inverter wired for 3-phase input. Note
the use of ring lug connectors for a secure connection.
Input wiring for single-phase input
(-SFEF and -NFU models)
CAUTION: Power terminal assignment is different compared to old models such as L100, L200
series, etc,. Pay attention when wiring the power cable
Models 002S~004S,
Number
002N~004N
of Screw
Terminals
Screw
Diameter
5
M3.5
8(dual in row)
M3.5
7
15
M2
3
M3
Screw
Tightening Torque
M3.5 0.8N m (max. 0.9 N m)
M4
1.2N m (max. 1.3 N m)
Models 007S~022S,
007N~022N,037L,
004H~040H
Width
Screw
Width
(mm)
Diameter
(mm)
7.1
M4
9.2
7.1
M4
9.2
M2
M3
Screw
M5
Input wiring for 3-phase input
(models -NFU, -LFU, -HFEF, -HFU)
Models 055~075L/H
Screw
Width
Diameter
(mm)
M5
12
M5
12
M2
M3
Tightening Torque
2.0N m (max. 2.2 N m)