Func.
Name
Code
A092
Acceleration (2) time
(high)
setting
A092
(low)
A292
Acceleration (2) time
(high)
setting,
2nd motor
A292
(low)
A093
Deceleration (2) time
(high)
setting
A093
(low)
A293
Deceleration (2) time
(high)
setting,
2nd motor
A293
(low)
A094
Select method to
switch to Acc2/Dec2
profile
A294
Select method to
switch to Acc2/Dec2
profile, 2nd motor
A095
Acc1 to Acc2 frequency
transition point
A295
Acc1 to Acc2 frequency
transition point, 2nd
motor
A096
Dec1 to Dec2 frequency
transition point
A296
Dec1 to Dec2 frequency
transition point, 2nd
motor
A097
Acceleration curve
selection
A098
Deceleration curve
selection
A101
[OI]-[L] input active
range start frequency
A102
[OI]-[L] input active
range end frequency
A103
[OI]-[L] input active
range start current
List of Holding Registers
R/W
Description
R/W
Duration of 2nd segment of
acceleration, range is:
R/W
0.01 to 3000 sec.
R/W
Duration of 2nd segment of
acceleration, 2nd motor, range is:
0.01 to 3000 sec.
R/W
R/W
Duration of 2nd segment of
deceleration, range is:
0.01 to 3000 sec.
R/W
R/W
Duration of 2nd segment of
deceleration, 2nd motor, range is:
0.01 to 3000 sec.
R/W
R/W Two options for switching from
1st to 2nd accel/decel:
00
2CH input from terminal
01
Transition frequency
R/W Two options for switching from
1st to 2nd accel/decel:
00 2CH input from terminal
01 Transition frequency
(2nd motor)
R/W Output frequency at which
Accel1 switches to Accel2, range
is 0.0 to 400.0 Hz
R/W Output frequency at which
Accel1 switches to Accel2, 2nd
motor, range is 0.0 to 400.0 Hz
R/W Output frequency at which
Decel1 switches to Decel2, range
is 0.0 to 400.0 Hz
R/W Output frequency at which
Decel1 switches to Decel2, 2nd
motor, range is 0.0 to 400.0 Hz
R/W Set the characteristic curve of
Acc1 and Acc2, two options:
00 linear
01 S-curve
R/W Set the characteristic curve of
Dec1 and Dec2, two options:
00 linear
01 S-curve
R/W The output frequency
corresponding to the analog
input range starting point,
range is 0.0 to 400.0 Hz
R/W The output frequency
corresponding to the current
input range ending point,
range is 0.0 to 400.0 Hz
R/W The starting point (offset) for the
current input range,
range is 0. to 100.%
B − 29
B 29
Network Data
Reg.
Range
Res.
1074h
1 to
0.01 sec
300000
1075h
*1
1519h
1 to
0.01 sec
300000
*1
151Ah
1076h
1 to
0.01 sec
300000
*1
1077h
151Bh
1 to
0.01 sec
300000
*1
151Ch
1078h
0, 1
151Dh
107Ah
0 to 4000
0.1 Hz
151Fh
107Ch
0 to 4000
0.1 Hz
1521h
107Dh
0, 1
107Eh
0, 1
1080h
0 to 4000
0.1 Hz
1082h
0 to 4000
0.1 Hz
1083h
0 to 100
1 %