Mitsubishi Electric e Series Service Handbook page 77

Air-cooled chilling unit r410a
Hide thumbs Also See for e Series:
Table of Contents

Advertisement

[ V Electrical Wiring Diagram ]
MAIN BOX
Power supply
3N
50/60Hz
TERMINAL
BOX
TB1
TB4
L1
L1
L2
L2
L3
L3
N
N
FG
FANCONT
BOX
No-voltage contact input
1
Run
2
Fan mode
*
3
Cooling/Heating switching
4
Pump interlock
*
5
Anti freeze
6
Capacity change mode
7
Flow switch
8
Outlet water temp. switching
Demand
9
*
10
Mode change
SUB BOX
TB2
L1
L2
L3
N
Note1. Faston terminals have a locking function.
Press the tab in the middle of the terminals to remove them.
Check that the terminals are securely locked in place after insertion.
Note2. Remove the short circuit wire between the terminals K10 and K11 to connect a flow switch.
Note3. Be sure to connect the wires from terminals K4 and K6 to the interlock contact on the pump.
A short-circuit may cause abnormal stop or malfunctions.
Note4. Operation signals can be received from through the No-voltage contact.
Note5. Use a 4-20mA signal output device with insulation.
Feeding 30mA or more current may damaged the circuit board.
Note6. Make sure that on site terminal connection is correct.
With wrong connection,operation error may occur.
Note7. Leave a space of at least 5 cm between the low voltage external wiring (No-voltage contact
input and remote controller wiring) and wiring of 100V or greater. Do not place them in the
same conduit tube or cabtyre cable as this will damage the circuit board.
The specification of the product might be changed without a previous notice for the improvement.
HWE1417B
3
Noise Filter1-1
2
CN1A
1
4
3
2
CN1B
1
L1
TB21
TB22
TB23
TB24
U
Z5
R4
DB1
L2-A
N1
3
2
To M-NET
To M-NET
CN04(3)
CN04(1)
No-voltage contact output
*
11
Defrost signal output
*
12
Heating operation display output
13
Operation display output
14
Error display output
15
Pump operation command output
16
Drain pan heater signal output
*
17
Supplementary heater signal output
(FROM SUB BOX)
3
Noise Filter2-1
2
CN1A
1
4
3
2
CN1B
1
L2
TB21
TB22
TB23
TB24
U
Z5
Z5
R4
DB1
L3-A
N2
3
2
6
5
4
4
3
CN2
3
2
2
1
1
red
white
black
C11
D1
R5
R6
CN5
CN3
CN4
1
red
3
2
1
blue
3
2
1
200VAC
CNAC
red
2
1
3
2
CNDC
1
pink
4-way value
(EAHV only)
*
,
are enabled only EAHV-P900YAF, EAHV-P900YAL
3
12
5 10 11
,
,
are disabled only EACV-P900YAF, EACV-P900YAL
,
are enabled only during the heating.
11 17
6
5
4
4
3
CN2
3
2
2
1
1
red
white
black
C11
D1
R5
R6
CN5
CN3
CN4
1
red
3
2
1
blue
3
2
1
200VAC
CNAC
red
2
1
3
2
CNDC
1
pink
4-way value
(EAHV only)
(EAHV only)
Note8. When cabtyre cable is used for the control cable wiring,
use a separate cabtyre cable for the following wiring.
Using the same cabtyre cable may cause malfunctions and damage to the unit.
(a) Optional remote controller wiring
(b) No-voltage contact input wiring
(c) No-voltage contact output wiring
(d) Analog input wiring
Note9. Use a contact that takes 12VDC 1mA for No-voltage contact input.
When a power supply voltage of 380 V, 400 V, or 415 V is applied, the output
voltage of 200 VAC, 230 VAC, or 240 VAC will be output from the dry contact
respectively. Use the unit in between the 10 mA and 1 A range.
- 68 -
C100
R11,R12
DCL1
52C1
2
1
3
4
7
6
5
4
3
2
CN2
SC-P2
FT-P
SC-P1
red
black
INV Board 1
C1
FT-N
C30,C32
C31,C33
RSH1
CN1
ZNR001
C34,C36
C35,C37
U
R30,R32,R34
R31,R33,R35
SC-L1
DS
IPM
SC-L2
SC-L3
CT3
Discharge
Air hex
Outdoor
Water
Water hex
Water
Water
Ref
Ref
temp
inlet
Ref
outler
inlet
temp.1
temp.1
temp.2
temp.1
temp
temp.1
TH11
TH6
TH10
TH2
TH7
TH3
TH1
2
1
2
1
2
1
6
5
4
3
2
1
4
3
2
CN404
CN405
CN406
CN407
CN401
black
blue
yellow
red
F01
AC250V
X01
X03
X02
3.15A T
CN501
CN502
3 2 1
6
5
4
3
2
1
TERMINAL
MV1
BOX
H1
Case heater
C200
R21,R22
DCL2
52C2
2
1
3
4
7
6
5
4
3
2
CN2
SC-P2
FT-P
SC-P1
red
black
INV Board 2
C1
FT-N
C30,C32
C31,C33
RSH1
CN1
ZNR001
C34,C36
C35,C37
U
R30,R32,R34
R31,R33,R35
SC-L1
DS
IPM
SC-L2
SC-L3
CT3
Acc
Discharge
Air hex
Water hex
High
inlet
Ref
Ref
Ref
Ref
pressure
temp.2
temp.2
temp.2
sensor.2
temp.2
TH21
TH26
TH27
TH25
HP2
1
2
3
2
1
2
1
6
5
4
3
2
1
2
1
3
2
1
CN404
CN406
CN401
CN408
CN63HS
black
yellow
F01
AC250V
X01
X03
X02
3.15A T
CN501
CN502
3
2
1
6
5
4
3
2
1
TERMINAL
TB6
MV2
BOX
H2
Case heater
1
2
CN6
1
2
CN43
1
yellow
3
2
CNTYP
1
CT12
SC-U
SC-V
CT22
SC-W
Acc
High
inlet
pressure
Ref
sensor.1
temp.1
TH5
HP1
1
2
3
1
2
1
3
2
1
CN408
CN63HS
X05
X04
CN510
7 6 5 4 3 2 1
TB6
K64
K63
K62
K61
16
15
1
2
CN6
1
2
CN43
1
yellow
3
2
CNTYP
1
CT12
SC-U
SC-V
CT22
SC-W
Low
High pressure
pressure
sensor.2
switch.2
LP2
63H2
1
2
3
3
2
1
3
2
1
CN801
CN63LS
yellow
X05
CN510
7 6 5 4 3 2 1
K52
K51
17
GB