Mitsubishi Electric e Series Service Handbook page 158

Air-cooled chilling unit r410a
Hide thumbs Also See for e Series:
Table of Contents

Advertisement

[ IX Troubleshooting ]
Sub Compressor Replacement Instructions
1
2
Decoration panel SL
panel SL
Panel SL
Panel SL
Panel F
Panel F
3
Control box
ntrol box
4
5
HWE1417B
Pipe connections
Fixing screws
Fixing screws
1. Switch off the power of the unit.
Before collecting refrigerant from the unit, drain water from the
plate heat exchanger to keep the water from freezing and
damaging the unit.
2. Collect the refrigerant.
1. Remove the decoration panel SL and panels SL and F on the
front of the unit.
1. Remove the control box.
1. Remove the belt heater and the wires.
2. Debraze the pipe connections at two locations.
3. Unscrew the four fixing screws, and remove the compressor.
4. Install the new compressor.
5. Connect the pipes by brazing.
6. Re-place the belt heater and the wires.
1. Re-place the control box.
2. Re-place the decoration panel SL and panels SL and F.
3. Charge the unit with refrigerant.
- 149 -
GB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents