[ IX Troubleshooting ]
Abnormal stop condition table
Error code
1102
Discharge temperature fault
1138
Hot water abnormal rise
1176
Discharge SH fault
1189
ACC inlet SH fault
1301
Low pressure fault
1302
High pressure fault
1303
1503
Cold water abnormal drop
1510
Gas leak fault
1512
Low evaporation temperature fault
2500
Water supply cutoff (Flow switch)
2501
Water supply cutoff (Sensor)
2550
4102
Open phase
4106
Power supply fault
4115
Power supply frequency fault
4116
Fan motor fault
4122
Fan interlock fault
4126
Analog input error
422*
Inverter bus voltage fault
423*
Inverter overheat protection fault
424*
Inverter overload protection
425*
IPM error (inclusive)/overcurrent relay
426*
Cooling fan fault
5101
Water inlet temp 1 thermistor error (TH1)
5102
Water inlet temp 2 thermistor error (TH2)
5103
Water inlet temp 3 thermistor error (TH3)
5105
ACC inlet refrigerant temperature thermistor error (TH5/TH25)
5106
Air heat exchanger refrigerant thermistor error (TH6/TH26)
5107
Water heat exchanger refrigerant thermistor error (TH7/TH27)
5110
Outdoor temperature thermistor error (TH10)
5111
Discharge refrigerant temperature thermistor error (TH11/TH21)
5114
THHS sensor/Circuit fault
5115
External water sensor fault
5201
High pressure sensor fault
5202
Low pressure sensor fault
530*
ACCT sensor fault/Circuit fault
0403
Serial communication error
6500
Communication error between the MAIN and SUB units
6600
Communication error between the MAIN and SUB units
6602
Communication error between the MAIN and SUB units
6603
Communication error between the MAIN and SUB units
6606
Communication error between the MAIN and SUB units
6607
Communication error between the MAIN and SUB units
6608
Communication error between the MAIN and SUB units
6831
Remote controller signal reception error 1
6832
Remote controller signal transmission error
6834
Remote controller signal reception error 2
6833
Remote controller over current
7113
Model setting error
7117
: One side circuit can be operated.
: Another module can be operated.
: Operation impossible
: Not abnormal stop
*1: Case of the one pump system
*2: Case of the communication error between the MAIN and SUB circuits
*3: " * " in the error code column shows types of components. (0/1: COMP for MAIN circuit, 2: COMP for SUB circuit, 5: FAN 1, 6: FAN 2, 7: FAN 3)
HWE1417B
Error type
- 129 -
One side circuit can
Another module can
be operated
be operated
*1
*2
GB