Blades
NOTICE:
•
Wear safety gloves.
During normal operating conditions, the blades will become blunt after approximately
•
30–50 operating hours.
•
Signs of blunt blades:
o Abnormally noisy
o Reduced speed
o The V-belt slips (even after tightening)
The blades and counterknife can be
•
reversed once.
Blades
2x
Immediately replace faulty blades!
•
Loosen the screws, reverse the blades (grind as required) and fit them securely into
position again.
Adjust the distance between the counterknife and the blades to 0.5–1.0 mm.
Carburettor
NOTICE: The carburettor settings may only be set by a qualified professional!
P. Lindberg A/S
Tel.: +45 70212626
Counterknife
1x
25
Sdr. Ringvej 1
6600 Vejen, Denmark
Blades
Counterknife
E-mail: salg@p-lindberg.dk
MAN 9065033 EN V1
www.p-lindberg.dk