If there is fertiliser in the
hopper
74. Level sensor (FH)
Level sensor error
75. Supply voltage for FH
is too low
76. Supply voltage for FH
motor is too low
77. FH fault, motor 1
78. Temperature is too
high (FH)
79. Temperature is too low
(FH)
80. CAN timeout for GW
to FH
81. CAN timeout for FH to
GW
82. Maximum speed
The motor is running at
full speed but the feed rate
has not been achieved
903075-en-gb; 07.06.2017
The sensitivity of the sensor has been incorrectly set.
Check the sensor's cable, contacts and connections.
Check that the sensor is not dirty or damp. Wipe the sensor clean with a dry cloth.
The sensor may be defective.
Check that the connectors and supply cables from the tractor to FH are correctly
connected.
Check the tractor's charging voltage.
Check that the connectors and supply cables from the tractor to FH are correctly
connected.
Check the tractor's charging voltage.
Check the gear setting and cabling
Check the power supply to the output unit.
Check the cabling, connectors and connections.
The machine will not start or stops because the system has been overloaded.
Check and clean the output unit if it has stopped.
Wait until the machine has cooled down. Upper limit 80°C.
The machine will not start because the temperature has dropped below the permissible
limit (-5°C) for an appropriate output working temperature.
The time limit for CAN communication between Gateway and FH has expired.
Check that the motor outputs on FH are configured.
Check the cabling between Gateway and FH.
The time limit for CAN communication between Gateway and FH has expired.
Check that the motor outputs on FH are configured.
Check the cabling between Gateway and FH.
Check that the feed rate is not set to a value that is too high
The system is not capable of delivering the desired feed rate if the feed rate is set too
high.