Work Display; Function Buttons - Vaderstad E-Services TPF Series Instructions Manual

Table of Contents

Advertisement

the row unit to be changed. Restart the output by pressing
the same row unit again.
When you raise and lower the machine, all row
units always start automatically.
Bars
A. Row number
B. The number of doubles – The bar indicates the row
unit's number of doubles as a percentage.
C. The number of skips – The bar indicates the row
unit's number of skips as a percentage.
Bar colours
Drilling quality here refers to the number of skips and the
number of doubles.
Green bar = drilling quality within approved area,
Yellow bar = drilling quality is >= 50% of set alarm
level
Red bar = drilling quality is >= 100% of set alarm
level
The levels for the different alarms are set in the alarms
menu in basic settings.
11.1.2

Work display

Figure 11.3
Fields on the home screen:
A. Seed feed rate Depending on the calibration
method, either seed spacing or the amount of seed
per hectare will be displayed.
B. Fertiliser rate The feed can be switched off and on
by pressing the fertiliser symbol.
C. Micro-granulate feed rate The feed can be
switched off and on by pressing the micro-granulate
symbol.
903075-en-gb; 07.06.2017
Virtual Terminal (ISOBUS)
D. Adjustment of sown seed amount Pressing the
field for the seed or fertiliser feed rate will cause a
pop-up window for variable adjustable feed rate to
appear. See "12.10.2 Virtual Terminal (ISOBUS)".
E. Fan rpm
or air pressure
has been selected,
Press the field to switch value.
F. Operation speed
G. Tramlining The first number shows which phase of
the tramlining cycle you are in. The second number
is the number of tramlining cycles selected in the
tramlining menu. Here it is possible to advance up
through the bouts in numerical order.
H. Bout marker switching Shows the current position
of the bout marker arms. Press the field to switch
bout marker. Switches manually or automatically
depending on selection with the function button.
.
I. Area meter Shows area driven since latest reset.
During operation, it is a good idea to check at
regular intervals that the air pressure in the seed
feed housing is maintained at 3.5 kPa.
11.1.3

Function buttons

Figure 11.4 iPad function buttons
A. LowLift
B. Lift stop
C. Wing folding
D. Auto advance
E. Bout marker switching
F. Manual output
G. Transport position
H. Front hopper activation
If front hopper
is also displayed.
25

Advertisement

Table of Contents
loading

Table of Contents