Alarm list, ISOBUS/E-Control
11. Micro-granulate motor
voltage
12. Fertiliser motor voltage WS9 is overloaded so the thermal overload protection has tripped.
13. Current too high for
MOSFET sowing
14. Current too high for
MOSFET micro-granulate
15. Current too high for
MOSFET fertiliser
16. Programmable over-
current: seed
17. Programmable over-
current: micro-granulate
18. Programmable over-
current: fertiliser
19. Temperature sensor
fault: seed
20. Temperature sensor
fault: micro-granulate
21. Temperature sensor
fault: fertiliser
22. Temperature too high:
seed
23. Temperature too high:
micro-granulate
56
WS9 is overloaded so the thermal overload protection has tripped.
The motor can be restarted as soon as the thermal protection has cooled.
Check the output and clean if a blockage has occurred.
The motor can be restarted as soon as the thermal protection has cooled.
Check the output and clean if a blockage has occurred.
There is thermal overload of the seed motor.
Check the hub and seed disc setting on the motor shaft.
There is thermal overload of the micro-granulate motor.
Check and clean the output unit if it has stopped.
There is thermal overload of the fertiliser motor.
Check and clean the output unit if it has stopped.
There is overload of the seed motor. The motor trips when the power supply exceeds
5 A.
Check the hub and seed disc setting on the motor shaft.
There is overload of the micro-granulate motor. The motor shuts down when the
power supply exceeds 1.5 A.
Check and clean the output unit if it has stopped.
There is overload of the fertiliser motor. The motor shuts down when the power
supply exceeds 1.5 A.
Check and clean the output unit if it has stopped.
The temperature in the sensor is too high.
Switch off and wait until the sensor has cooled.
The temperature in the sensor is too high.
Switch off and wait until the sensor has cooled.
The temperature in the sensor is too high.
Switch off and wait until the sensor has cooled.
The machine will not start or stops because the system has been overloaded.
Check and clean the output unit if it has stopped.
Wait until the machine has cooled down. Upper limit 80°C.
The machine will not start or stops because the system has been overloaded.
Check and clean the output unit if it has stopped.
Wait until the machine has cooled down. Upper limit 80°C.