Vaderstad E-Services TPF Series Instructions Manual page 36

Table of Contents

Advertisement

Virtual Terminal (ISOBUS)
Figure 11.17
Display
A. Calculates the number of pulses.
Calibration menu settings (Values are displayed either in
metric or imperial units, depending on which one has
been selected in the basic settings menu).
B. Set the required percentage increase/decrease rate in
feed volume in the feed rate field.
If you select, for example, 5%, the feed rate will
change in increments of 5% every time the button is
pressed in the operations menu.
C. Select which of the output units is to be calibrated (i.e.
a row with a calibration bag).
The position of the output units is the same as that of
the row units. If the calibration is to cover all output
units, select ON (default setting).
If calibration is to be carried out individually for only
one row unit, select OFF.
Not relevant when front hopper is used
D. Enter the required fertiliser rate.
E. Enter the weight of the contents of the calibration bag
filled during calibration.
F. Calculates pulses/kg. (You can also enter pulses/kg
manually by pressing the row and entering the value
in the pop-up window.)
G. Output for filling the output system.
H. Calibrate
32
Calibration
Figure 11.18
The calibration is normally carried out on one output unit
and the values are automatically carried over to the
others. If desired, it is also possible to calibrate one
output unit individually.
Before calibration, check that there is a sufficient
amount of fertiliser in the fertiliser hopper. The depth of
fertiliser in the hopper should be at least 15 cm.
1. Set the output units and select a output roller so that it
suits the current fertiliser type.
2. Enter the values in the calibration menu.
3. Fill the output system using the
4. Empty the calibration bag and put it back in place.
5. Select the calibration button and hold this button in
until the right amount of fertiliser has been fed into
the calibration bag. The pulses from the output are
displayed alongside the pulse symbol.
6. Weigh the contents of the calibration bag. Tip: First
reset the scales with an empty calibration bag.
7. Enter the weight of the contents of the calibration bag
in field (E) in the calibration menu. The number of
pulses per kg will be automatically displayed in field
(F).
To enter the number of pulses manually, press field
(F) and specify the number of pulses in the pop-up
window. To cancel the calibration and perform a
fresh calibration, repeat points 3 to 7.
8. You can exit the calibration menu using
directly to calibration of another unit.
9. Reset the calibration flaps to position B for drilling.
Figure 11.19
1
2
3
4
5
6
7
8
9
button.
, or go
B
903075-en-gb; 07.06.2017