Description Of The Connectors / Interfaces - LinMot E1200-GP-UC Installation Manual

Servo controller
Hide thumbs Also See for E1200-GP-UC:
Table of Contents

Advertisement

LinMot Installation Guide

6 Description of the connectors / Interfaces

6.1 X1
X1
Motor Supply / Regeneration Resistor
Screw Terminals
External Regeneration Resistor (RR01-10/60, Art. Nr. 0150-3088)
External Fuse: max. 32AT (for example RK5 Class Fuse Bussmann FRN-R-30)
Supply nominal 72VDC (24...85VDC / 30..85VDC for UL compliance)
(See chapter Power Supply Requirements for compatible power supplies.)
Absolute max. Rating 72VDC +20%.
If motor supply voltage is exceeds 90VDC, the controller will go into error state.
6.2 X2
X2
Motor Phases
PH1+
PH1-
PH2+
PH2-
SCRN
Screw Terminals
®
NTI AG / LinMot
- Tightening torque: 0.5 - 0.6 Nm
- Screw thread: M2.5
- Use 60/75°C copper conductors only
- Conductor cross-section: use only 2.5mm
- Stripping length: 13-15mm
- Max. length: 4m
LinMot Motor:
/U
Motor Phase 1+
/V
Motor Phase 1-
/W
Motor Phase 2+
/X
Motor Phase 2-
Shield
- Tightening torque: 0.5 - 0.6 Nm
- Screw thread: M2.5
- Use 60/75°C copper conductors only
- Conductor cross-section: 0.5 – 2.5mm
- Stripping length 13-15mm
www.LinMot.com
2
/ AWG 14
3-phase EC-Motor:
red
Motor Phase U
pink
Motor Phase V
blue
Motor Phase W
grey
Motor Phase X
2
(depends on Motor current) / AWG 21 -14
Page 8/20

Advertisement

Table of Contents
loading

Table of Contents