Leds; Rt Bus Leds; S1 - S2 - LinMot E1200-GP-UC Installation Manual

Servo controller
Hide thumbs Also See for E1200-GP-UC:
Table of Contents

Advertisement

LinMot Installation Guide
6.13
S5
S5
Bus Termination / AnaIn2 Pull Down
S5
Switch 1: AnIn2 Pull down (4k7 Pull down on X4.4). Set to ON, if X4.4 is used as digital Output.
Switch 2: Termination Resistor for RS485 on CMD (120R between pin 1 and 2 on X7/X8) on/off
Switch 3: CAN Termination on CMD (120R between pin 7 and 8 on X7/X8) on/off
Switch 4: CAN Termination on ME (120R between pin 7 and 8 on X10/X11) on/off
Factory setting: all switches "off"
6.14

LEDs

LEDs
State Display
Green
Yellow
Yellow
Red
6.15

RT BUS LEDs

RT Bus LEDs
RT Bus State Display
Green
Red
The use of these LEDs depends on the type of fieldbus which is used. Please see the corresponding
manual for further information.
6.16

S1 - S2

S1 - S2
Address Selectors
E12x0 V1
E12x0 V2
The use of these switches depends on the type of fieldbus which is used. Please see the corresponding manual for further
information.
®
NTI AG / LinMot
24V Logic Supply OK
Motor Enabled / Error Code Low Nibble
Warning / Error Code High Nibble
Error
OK
Error
S1 (5..8)
Bus ID High (0 ... F). Bit 5 is LSB, bit 8 MSB.
S2 (1..4)
Bus ID Low (0 ... F). Bit 1 is LSB, bit 4 MSB.
www.LinMot.com
Page 14/20