LinMot E1100-MP Installation Manual

Installation guide multi position servo controller
Hide thumbs Also See for E1100-MP:

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for LinMot E1100-MP

  • Page 1: Table Of Contents

    Multi Position Controller E1100-MP / -MP-HC Installation Guide Multi Position Servo Controller E1100-MP and E1100-MP-HC Content IMPORTANT NOTES FOR E1100 SERIES CONTROLLERS SYSTEM OVERVIEW E1100-MP SERIES FUNCTION AND WIRING E1100-MP-HC SERIES FUNCTION AND WIRING POWER SUPPLY AND GROUNDING DESCRIPTION OF THE CONNECTORS / INTERFACES...
  • Page 2: Important Notes For E1100 Series Controllers

    All connectors must not be connected or disconnected while DC voltage is present. Do not disconnect system components until all LinMot controller LED’s have turned off. (Capacitors in the power supply may not fully discharge for several minutes after input voltage been disconnected).
  • Page 3: System Overview

    Multi Position Controller E1100-MP / -MP-HC System Overview Complete Multi Position Servo System E1100-MP Servo Controller, Linear Motor and Power Supply. NTI AG Installation: E1100-MP /-MP-HC / 03.10.2005 Page 3/16...
  • Page 4: E1100-Mp Series Function And Wiring

    In Position 2 shielded cables 0.1A In Position 8 RS232 Multi Position Servo System E1100-MP Servo Controller, Linear Motor and Power Supply. All connections for the motor are done within the DSUB-9 connector. NTI AG Installation: E1100-MP /-MP-HC / 03.10.2005 Page 4/16...
  • Page 5: E1100-Mp-Hc Series Function And Wiring

    0.1A In Position 8 RS232 Multi Position Servo System E1100-MP-HC Servo Controller, Linear Motor and Power Supply. The motor connection is done by a DSUB-9 connector for the sensor signals and direct wire connections for the power lines (phases). NTI AG Installation: E1100-MP /-MP-HC / 03.10.2005...
  • Page 6: Power Supply And Grounding

    In order to assure a safe and error free operation, and to avoid severe damage to system components, all system components* must be well grounded to either a single earth or utility ground. This includes both LinMot and all other control system components to the same ground bus.
  • Page 7: Description Of The Connectors / Interfaces

    Multi Position Controller E1100-MP / -MP-HC Description of the connectors / Interfaces Motor Supply 24...72VDC Internal Fuse 16AT GND internally connected to controller housing Optional: Regeneration Resistor (external) Screw Terminals 24...72VDC Motor Supply Motor Supply: Motor Supply Voltage 24...72VDC. Absolute max. Rating 72VDC +10%.
  • Page 8 Note: - PS01-48x.. and PS01-37x240-F stators must be connected to X2 and X3 connectors of E1100-MP-HC controllers - Use only special double-shielded Linear Motor Cable. - Use +5V (X3.3) and AGND (X3.8) only for motor internal Hall Sensor supply (max. 100mA).
  • Page 9 Multi Position Controller E1100-MP / -MP-HC Control / Logic Supply GND +24VDC Logic Supply +24VDC Output Supply to X6 Outputs Internal Internal Fuse 3AT Fuse 3AT GND internally connected to controller housing +24V DC Logic Supply Outputs Digital I/O’s: Inputs 24V / 5mA / 1msec (Trigger Input 0.25msec)
  • Page 10 Multi Position Controller E1100-MP / -MP-HC Digital I/O DSUB-25 (f) All Inputs: Direct interfacing to digital 24VDC PLC outputs. Max. Low Level: <1.5V Min. High Level: >4.0V Input current: 0.5mA Sample rate: All Outputs: Short circuit and overload protected high side switches...
  • Page 11: Physical Dimension

    Multi Position Controller E1100-MP / -MP-HC Physical Dimension E1100-MP / E1100-MP-HC Single axes controller Width mm (in) 40 (1.6) Height mm (in) 250 (9.9) Height without fixings mm (in) 235 (9.3) Depth mm (in) 180 (7.1) Weight Kg (lb) 1.5 (3.3)
  • Page 12: Power Supply Requirement

    Multi Position Controller E1100-MP / -MP-HC Power Supply Requirement Power Supply motor The calculation of the needed power for the Motor supply is depending on the application and the used motor. Power Supply signal 24VDC min. 100mA (no load on the outputs) typ.
  • Page 13: Declaration Of Conformity Ce-Marking

    Multi Position Controller E1100-MP / -MP-HC Declaration of Conformity CE-Marking Manufacturer: NTI AG ® LinMot Haerdlistrasse 15 CH-8957 Spreitenbach Switzerland Tel.: +41 (0)56 419 91 91 Fax: +41 (0)56 419 91 92 ® Products: LinMot Controllers Type Art.-No. Type Art-No.
  • Page 14: Error Codes

    Multi Position Controller E1100-MP / -MP-HC Error codes In case of an error the following messages will be showed on the connected computer. Error ID Error Message Logic supply voltage too low Logic supply voltage too high Motor supply voltage too low...
  • Page 15: Contact Addresses

    Multi Position Controller E1100-MP / -MP-HC Contact Addresses NTI AG LinMot Tel. +41 (0)56 419 91 91 Haerdlistrasse 15 Fax. +41 (0)56 419 91 921 CH-8957 Spreitenbach email: office@LinMot.com Switzerland Web: www.LinMot.com LinMot Inc. N2444 Broad Street Phone +1-877-546-3270 or 262-728-2699...
  • Page 16: Installation: E1100-Mp /-Mp-Hc / 03.10.2005

    Multi Position Controller E1100-MP / -MP-HC Smart solutions are… NTI AG Installation: E1100-MP /-MP-HC / 03.10.2005 Page 16/16...

This manual is also suitable for:

E1100-mp-hc