10 Regeneration of Power / Regeneration Resistor

There are two possibilities to deal with power regeneration:
Option A:
Connect an additional capacitor to the motor power supply. It is
recommended to use a capacitor >= 10'000 µF
(install capacitor close to the power supply!)
Option B:
Install a regeneration resistor to X1 (RR+ and RR-). The threshold
value of the voltage depends on the used motor voltage power supply.
The max. threshold value must not exceed 88 VDC.
For UL applications, use option A.
Item
Capacitor
Regeneration Resistor
Regeneration Resistor

11 Ordering Information

Item
Description
E1250-PL-UC
POWERLINK Servo Controller
E1250-PN-UC
PROFINET Servo Controller
E1250-EC-UC
EtherCAT Servo Controller
E1250-SE-UC
sercos over EtherCAT Servo Controller
E1250-SC-UC
sercos Servo Controller
E1250-IP-UC
ETHERNET IP Servo Controller
E1230-DP-UC
PROFIBUS-DP Servo Controller
E1200-GP-UC
GENERAL PURPOSE Servo Controller
RS232
AC01-RJ45/Df-2.5-RS1
configuration cable

12 International Certifications

Certifications
Europe
®
NTI AG / LinMot
Description
Capacitor 10'000 µF / 100 V
R01-10/60
(10 Ohm, 60 W)
RR01-10/150
(10 Ohm, 150 W)
See chapter "14 Declaration of Conformity CE-Marking"
www.LinMot.com
Art. No.
0150-3075
0150-3088
0150-3090
Art. No.
72VDC/32A
0150-1760
72VDC/32A
0150-1762
72VDC/32A
0150-1763
72VDC/32A
0150-1898
72VDC/32A
0150-1764
72VDC/32A
0150-1761
72VDC/32A
0150-1766
72VDC/32A
0150-1771
0150-2143