(1) Put the connector plate to the base and secure using the mounting bolts.
Installation
(2) Connect power cable connector and install power cable clamp.
(3) Mount the power cable cover.
NOTE
When installing the connector plate, be careful of the
following.
Prevent the air tube from bending sharply inside the
manipulator. Also, do not block the air flow.
If there is a kink in the air tube, air flow is blocked while the
manipulator is operating and may cause a trouble.
T-B series Maintenance Manual Rev.1
Hexagon socket head cap button bolt
Tightening torque: 2.0± 0.1 N·m
Reference 7.3 Power Cable Cover
T3-B T6-B Maintenance 7. Covers