Epson T-B Series Maintenance Manual page 53

Scara robot
Hide thumbs Also See for T-B Series:
Table of Contents

Advertisement

Connector Plate
(1) Put the connector plate to the base and secure using the mounting bolts.
Installation
(2) Connect power cable connector and install power cable clamp.
(3) Mount the power cable cover.
NOTE
When installing the connector plate, be careful of the
following.
Prevent the air tube from bending sharply inside the
manipulator. Also, do not block the air flow.
If there is a kink in the air tube, air flow is blocked while the
manipulator is operating and may cause a trouble.
T-B series Maintenance Manual Rev.1
Hexagon socket head cap button bolt
Tightening torque: 2.0± 0.1 N·m
Reference 7.3 Power Cable Cover
T3-B T6-B Maintenance 7. Covers
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

T3-b401s, t6-b602s

Table of Contents