Restore - Epson T-B Series Maintenance Manual

Scara robot
Hide thumbs Also See for T-B Series:
Table of Contents

Advertisement

5.4 Restore

Restore the Manipulator status from the EPSON RC+ 7.0.
Make sure that the data used for restoring was saved previously for same
Manipulator.
■ Do not edit the backup files.
CAUTION
restoration to the Manipulator is not assured.
(1) Select the EPSON RC+ 7.0 menu-[Tools]-[Controller] to display the [Controller Tools]
(2) Click the <Restore Controller...> button to display the [Browse For Folder] dialog.
(3) Specify the folder to save the backup data.
Controller status backup to USB memory function can also be specified for restore. Specify
NOTE
the following folder
T-B series Maintenance Manual Rev.1
dialog box.
B_T_ serial number_ date status was saved
→ Example: B_T_12345_2016-04-03_092941
T3-B T6-B Maintenance 5. Backup and Restore
Otherwise, operation of the robot system after data
23

Advertisement