Troubleshooting Guide - Maxx Ice MIM150N Service, Installation, And Instruction Manual

Automatic commercial ice cube machine
Table of Contents

Advertisement

Troubleshooting Guide

PROBLEM
The machine doesn't
operate
The water doesn't feed in
after the ice maker starts
Machine makes ice, but bin
does not fill up with ice
Water is leaking out the unit
Cubes are partially formed--
are white at the bottom
Noise during operation
The icemaker stops suddenly
while making ice
The body of the ice maker is
electrified
Scales occur frequently inside
the machine
The ice cubes are not
completely formed when
being dumped
SERVICE AND INSTALLATION MANUAL
POSSIBLE CAUSE
The ice maker is unplugged
The fuse is blown
The ice maker power switch
is OFF
The ice storage bin is full of ice
The water supply tap is turn off
The water supply pipe is not
proper connected
The condenser may be dirty
The air flow to the ice maker
may be obstructed
The ambient temperature
and water temperature are
high, or it is near with some
heat resource
A few water drops to the
floor when you open the
door to take out ice from
ice storage bin
Water supply connection leaks
Not enough water in
the water bin
The feet are not leveled
Certain sounds are normal
The electricity is off
The room temperature is out
the state range
The earth line isn't in the socket
The hardness of the water qual-
ity is too high
The sprinkler is blocked
www.maxxfoodservice.com
PROBABLE CORRECTION
Plug the ice maker in
Replace fuse--if it happen, call for
service to check for a short circuit in
the ice maker
Turn the ice maker power switch
to ON
Take away some ice, make the ice-
full sensor is free of ice
Turn on the water supply tap
Reconnect the water supply pipe
Clean the condenser
Check the installation
Check the installation
Normal condensation on the door or
some water together with ice Take
care when you take out ice
Tighten fitting. See Connecting the
water line
Check if the water supply
pressure is below 15psig
Check water supply--filter may be
restricted
Check for a water leak at the water
tank
See Leveling the Ice Maker
See Normal Sounds
Reconnected the power
supply line
Cut off the electricity, let the ice
maker stop working till the tempera-
ture returns within the stated range
Please use the socket meeting the
standard
Using a water-soften apparatus
installed in front of the water inlet
Clean the sprinkler, see
"interior cleaning"