INSTALLING THE STABILITY BRACKETS

This operation requires at least two persons
If you wish to install the ice maker in a free-standing
mode rather than enclosed, it is necessary to attach
the two metallic stability brackets that can be found
packed inside the ice storage bin
machine tilted to the right, but not more than 45˚,
attach one bracket to the center of the underside
of the ice maker with two screws (supplied) See
illustration below Set the unit back on its four feet, then
tilt it forward in order to screw in the second bracket
on the underside of the unit opposite the first bracket.
Level the ice maker This operation will stabilize it for
free-standing operation

LOCATION REQUIREMENTS

This ice maker should be installed by qualified personnel.
NOTICE:
1 Before setting the ice maker inside a cabinet, connect the water supply pipe correctly
Untie the drain hose, insert it into the drain, and connect the power supply line
2 Do not kink or pinch the power supply line between the ice maker and wall or cabinet
Installation Clearance
• To ensure proper ventilation for your ice maker, the front of the unit must be completely
unobstructed
• When installing the ice maker under a counter, follow the recommended spacing dimensions
shown Allow at least 6" (150 mm) clearance at rear, and 1" (25 mm) at the sides and at the
top for proper air circulation The installation should allow the ice maker to be pulled forward for
servicing if necessary
• Choose a well-ventilated area with temperatures above 40 F (4 4 C) and below 110 F (43 3 C) This
unit MUST be installed in an area protected from the elements, such as wind, rain, water spray or
drips
• The unit should not be located next to ovens, grills or other sources of high heat
• Installation of the ice maker requires a cold water supply inlet of 3/8" (9 5 mm) soft copper tubing
with a shut-off valve
• The ice maker requires a continuous water supply with a minimum pressure of 15 psig and a static
pressure not to exceed 80 psig The temperature of the water feeding into the ice maker should
o
be between 40 F(4 4 C) and 90 F (32 C) for proper operation