Connecting an AC burner
A To the control unit
B To the burner
Burner without plug
Install the mating plug from
Viessmann or from the burner manu-
facturer; connect the burner cable.
(cont.)
Terminal codes
L1
Phase via high limit safety cut-
out to the burner
PE
Earth conductor to burner
N
Neutral conductor to burner
T1, T2 Control chain
S3
Connection for burner fault
B4
Connection for hours run
meter
~
Signal pass direction:
Control unit
|
Signal pass direction:
Burner
Equipment codes
STB Control unit high limit safety cut-
out
TR
Control unit control thermostat
H1
Burner fault signal
BZ
Hours run counter
Installation sequence
burner
control unit