4- TURNING ON YOUR MONITOR

The Movement Sensor Pad alarm will sound after a few seconds if the child is not in the cot.

NURSERY UNIT

PAUSING AND RESTARTING THE
SENSOR PAD
• Allows you to pause the Sensor Pad if you
remove baby from the cot, e.g. for feeding
or comforting. The button has a soft light so
easily seen. Ensure to un-pause the Sensor
Pad before putting baby in the cot.
TEST THE SENSOR PAD
1. Sources of vibration & movement other than your baby's can be detected by the Sensor Pad and
interfere with the performance of your Angelcare monitor. The alarm will not sound if it detects
movement other than your baby's.
2. There are 4 sensitivity settings. The unit is set at level 3 (default) and can be adjusted accordingly.
3. The Sensor Pad will detect false movements if you are touching the cot.
4. The monitor will produce a Rouse alarm single beep tone designed to stir baby if no movement.
has been detected for 15 seconds. If no further movement is detected, the main alarm will sound
at 20 seconds – a series of continuous beeps.
SENSOR PAD FOUR CORNER TEST
1. Place the Sensor Pad at the approximate centre of baby's sleeping area and put the mattress
back in place.
2. Switch ON both Nursery & Parent Units – check both units are paired (connected).
3. Immediately pat your hand lightly and continuously on a corner of the mattress
twice for Sensor to detect movement. If movement is detected you will hear a
TIC sound every 5 seconds and PU will flash green for a single sensor pad.
4. Step away from the cot.
5. The alarm will sound from the Nursery and Parent Unit after 20 seconds.
If the Alarm does not sound, ensure everything is setup correctly and try
again; check battery levels on all units, follow the manual for 'NO ALARMS'
– the sensitivity setting may require lowering by a single level due to other
vibrations/movements.
6. If the alarm sounds, pat your hand lightly on a corner of mattress twice for
Sensor to detect movement. It may take up to 8 seconds to recognise movement and for alarm to stop.
7.
If the alarm continues, even after lightly patting the corner of your mattress twice, adjust the
sensitivity higher and repeat this test.

PARENT UNIT

NURSERY UNIT
Note:
• Your Nursery Unit and Parent Unit
come pre-paired.
• Each time you power ON your
Nursery Unit, the internal
thermometer will need to
calibrate to ensure accuracy.
This automatic process will take
approximately 30 minutes.