Streaming Page - Fluke SV600 Series User Manual

Sonic viewer
Table of Contents

Advertisement

SV600 Series
Users Manual, Rev. 2.1, Nov 2021
From/to Frequency can be used to set the frequency used in generation of the sound intensity
Leq event time is for how long the SV600 should average the sound intensity before checking the
threshold. This also determines the minimal time between two triggers.
Press update to apply the From/To frequency and Leq event time settings.
Use the threshold slider or input box to set the sound intensity level which should be reached before
sending an event
Use the event log slider or input box to set how many event to display on the right
Use the CS button export to export the events in ".csv" format or the TXT button for ".txt" format

5.3 Streaming Page

Using the spectrogram live feed (to the right on the image below), a user can see in which frequency bands the
most sound is detected. Red colors represent high intensity, blue colors represent low intensity.
The main view shows the user where the most sound is coming from in the selected frequency band. The band
used can be seen by the orange outline in the spectrogram plot. The current sound intensity dB(Z) can be seen in
the color bar and in the min/max pressure to the left.