Vega MINITRAC 31 Operating Instructions Manual page 78

Radiometric sensor for density measurement
Table of Contents

Advertisement

11 Supplement
Electromechanical data - version IP66/IP67
Options of the cable entry
Ʋ Cable entry
Ʋ Cable gland
Ʋ Blind plug
Ʋ Closing cap
Material ca-
Material seal
ble gland
insert
PA
NBR
Brass, nickel-
NBR
plated
Stainless
NBR
steel
Flammability class - Supply lines
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, stranded wire
Ʋ Stranded wire with end sleeve
Integrated clock
Date format
Time format
Time zone, factory setting
Max. rate deviation
Additional output parameter - Electronics temperature
Output of the temperature values
Ʋ Analogue
Ʋ Digital
Range
Resolution
Accuracy
Voltage supply
Operating voltage
Ʋ Sensor power supply
Ʋ FF bus
Electrical protective measures
Application area
Altitude above sea level
78
M20 x 1.5; ½ NPT
M20 x 1.5; ½ NPT (cable diameter see below table)
M20 x 1.5; ½ NPT
½ NPT
4.5 ... 8.5 mm
5 ... 9 mm
at least VW-1
0.2 ... 2.5 mm² (AWG 24 ... 14)
0.2 ... 1.5 mm² (AWG 24 ... 16)
Day.Month.Year
12 h/24 h
CET
10.5 min/year
Via the current output
Via the digital output signal (depending on the electron-
ics version)
-40 ... +50 °C (-40 ... +122 °F)
< 0.1 K
±5 K
24 ... 65 V DC (-15 ... +10 %) or 24 ... 230 V AC
(-15 ... +10 %), 50/60 Hz
9 ... 32 V DC
Outdoor areas
2000 m (6561 ft)
Cable diameter
6 ... 12 mm
MINITRAC 31 • Foundation Fieldbus
7 ... 12 mm
10 ... 14 mm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents