8.4 Blade Bolt Inspection

Inspect Blade Bolt Head daily for wear as follows:
Avoid personal injury. Always block the cutter up to prevent if from falling when the blades and/
or carrier are being serviced.
Visible cracks or
If the recessed area on blade bolt is worn off or
If Blade Bolt has gouges or chipped areas.
Failure to replace abnormally worn blade bolts may lead to catastrophic failure of the blades and ejection of the
broken part which may cause serious bodily injury or death.
Always replace Blade Bolts with new bolts whenever replacing the Blades. OPS-U-0037 str
TR308 04/21