21.0 GENERAL ORDINARY MAINTENANCE REQUIRES TRAINED PERSONNEL

BEFORE CARRYING OUT ANY MAINTENANCE JOBS IT IS OBLIGATORY TO STOP THE MACHINE AND DISCONNECT IT
FROM THE POWER MAINS.
MAINTENANCE SCHEDULE
These maintenance intervals are recommended for work environments that are not dusty and are will ventilated. For particularly dusty
environments, double the frequency of controls.
Every Day
Every 50 working hours
Every 500 hours
Every 2000 hours
Every 4000 hours
Every 8000 hours
Every 24000 hours
N.B.: THE OPERATIONS MARKED  ARE DESCRIBED IN PART "A" OF THIS MANUAL ON CHAPTER 15.2
(
) Or as indicated by oil analysis.
Oil specifications:
It is strongly recommended to use genuine lubricants from your manufacturer. They are the result of years of field experience and research.
See section Preventive maintenance schedule for the advised replacement intervals and consult the Spare Parts list for part number
information.
AVOID MIXING LUBRICANTS OF DIFFERENT BRANDS OR TYPES AS THEY MAY NOT BE COMPATIBLE AND THE OIL
MIX MAY HAVE INFERIOR PROPERTIES.
.
Purge condensate water from air receiver
Observe for unusual noise or vibration
Drain condensate from the oil tank
Check the oil level
Clean the filtering panel (VSD)
Clean the filter of the automatic discharge of condensate (dryer)
Check air receiver automatic drain (if applicable)
Fixing electrical cables (at first 500 hrs)
Clean the air suction filter
Clean the condenser battery (on the dryer if fitted)
Clean the dirt collection filter
Check automatic condensation emptying (dryer)
Clean the water separator drain
Clean the filtering panel (VSD)
Clean the air suction filter
Clean the air filters
  Maintenance kit of the automatic condensate drain (dryer)
  Clean the finned surface of the air-oil cooler
Change the filtering panel (VSD)
  Replace the oil separator cartridge
  Change the oil filter
Change the air filters
Change the air suction filter
  Retighten all power cable connections
  Safety temperature test
  Change the oil (
)
  Kit revision intake valve
  Checking the status of the oil return valve and oil pipes
  Kit revision minimum pressure valve
  Kit revision thermostatic valve
  Replace drain
  Kit revision of the compressor unit
  Kit revision of motor (bearings)
Cod. 9828093052 04 - Edition 02/2018 - 41