Quincy Compressor HP 15 Manual Use And Maintenance page 15

Table of Contents

Advertisement

Control panel
Function keys of the controller
Reference
Designation
1
Display
2
Automatic operation symbol
3
LED, Automatic operation Indicates that the regulator is automatically controlling the compressor: the compressor is loaded,
4
Warning symbol
5
LED, Warning
6
Voltage symbol
7
LED, Voltage on
8
Service symbol
9
LED, Service
10
Start button
11
Stop button
12
Scroll buttons
13
Enter button
14
Escape button
CAUTION: WAIT AT LEAST 20 SECONDS BEFORE STARTING THE MACHINE AFTER SWITCH OFF.
CAUTION: IN CASE OF START UP OR RESTART AFTER EMERGENCY STOP /ARAVF/ SHUT DOWN (SEE INSTRUCTION BOOK),
REFRIGERANT DRYER WILL RUN AFTER A DELAY OF 180 SECONDS; (ONLY FOR COMPRESSOR WITH
DRYER (SERIES "E8" R410A).
.
1
10
0
11
12
Shows icons and operating conditions.
unloaded, stopped and restarted depending on the air consumption and the limitations
programmed in the regulator.
It's lit if a warning condition exists.
Indicates that the voltage is switched on.
It's lit when service is needed.
This button starts the compressor. Automatic operation LED (3) lights up. The Elektronikon is
operative.
This button is used to stop the compressor. Automatic operation LED (3) goes out.
Use these buttons to scroll through the menu .
Use this button to confirm the last action.
Use this button to go to previous screen or to end the current action.
8
2
4
5
9
3
7
14
13
6
Function
Cod. 9828093052 04 - Edition 02/2018 - 15
ENGLISH
FIG. 17A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hp 20Hp 25Hp 30

Table of Contents