Quincy Compressor HP 15 Manual Use And Maintenance page 18

Table of Contents

Advertisement

ENGLISH
Typical Main screen (2 value lines), fixed speed compressors
Text on figures
(1)
Compressor Outlet
(2)
Element outlet
(3)
Load, ... (text varies upon the compressors actual condition)
(4)
Menu
(5)
Running hours
(6)
Flow (only VSD compressors)
Section A shows information regarding the compressor operation (e.g. the outlet pressure or the temperature at the compressor outlet). On
compressors with a frequency converter, the load degree (flow) is given in % of the maximum flow.
Section B shows Status icons. Following icon types are shown in this field:
Fixed icons
These icons are always shown in the main screen and cannot be selected by the cursor (e.g. Compressor stopped or running, Compressor
status (running, running unloaded or motor stopped).
Optional icons
These icons are only shown if their corresponding function is activated (e.g. week timer, automatic restart after voltage failure, etc.)
Pop up icons
These icons pop up if an abnormal condition occurs (warnings, shutdowns, service, ...)
To call up more information about the icons shown, select the icon concerned using the scroll keys and press the enter key.
Section C is called the Status bar. This bar shows the text that corresponds to the selected icon.
Section D shows the Action buttons. These buttons are used:
To call up or program settings
To reset a motor overload, service message or emergency stop
To have access to all data collected by the regulator
The function of the buttons depends on the displayed menu. The most common functions are "Menu" (To go to the menu),
"Modify" (To modify programmable settings), "Reset" (To reset a timer or message)
To activate an action button, highlight the button by using the Scroll keys and press the Enter key. To go back to the previous menu, press
the Escape key.
Chart views
Instead of viewing values, it is also possible to view a graph of one of the input signals (see section Inputs menu) in function of the time.
High Resolution
When Chart (High Resolution) is selected, the chart shows the variation of the selected input (in this case the pressure) per minute. Also the
instantaneous value is displayed. The screen shows the last 4 minutes.
The switch button (icon) for selecting other screens is changed into a small Chart and is highlighted (active).
When the Chart (Medium Resolution) is selected, the chart shows the variation of the selected input per hour. The screen shows the last 4
hours.
When the Chart (Low Resolution) is selected, the chart shows the variation of the selected input per day. The screen shows the evolution
over the last 10 days.
18 - Edition 02/2018 Cod. 9828093052 04 -
Typical Main screen (4 value lines), fixed speed compressors
Medium Resolution
Low Resolution

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hp 20Hp 25Hp 30

Table of Contents