Quincy Compressor HP 15 Manual Use And Maintenance page 23

Table of Contents

Advertisement

Outputs menu
Function: to call up information regarding the actual status of some outputs.
Procedure: starting from the Main screen (see Main screen), move the cursor to the action button Menu and press the Enter key, move the
cursor to the Outputs icon (see below).
Press the Enter key. A screen similar to the one below appears:
Outputs screen (typical)
The screen shows a list of all outputs with their status.
Counters
Function: to call up the running hours, the loaded hours, the number of motor starts, the number of hours that the regulator has been
powered and the number of load cycles.
Procedure: starting from the Main screen (see Main screen), move the cursor to the action button Menu and press the Enter key. Using the
Scroll keys, move the cursor to the Counters icon (see below)
Press the Enter key. A screen similar to the one below appears:
The screen shows a list of all counters with their actual readings.
Note: the example above is for a fixed speed compressor. In case of variable speed drive compressor, the actual screen will be somewhat
different.
.
(1)
Outputs
(2)
Line contactor
(3)
Star contactor
(4)
Delta contactor
(5)
Load/Unload
(1)
Counters
(2)
Running hours
(3)
Loaded hours
(4)
Motor starts
(5)
Load relay
Cod. 9828093052 04 - Edition 02/2018 - 23