15.9 CHECKING THE AUTOMATIC CONDENSATION EMPTYING (WITHOUT DRYER )
BEFORE CARRYING OUT ANY MAINTENANCE IT IS OBLIGATORY TO STOP THE MACHINE AND DISCONNECT IT FROM
THE POWER MAINS AND FROM THE COMPRESSED AIR DISTRIBUTION NETWORK.
The automatic and manual condensation emptying should be checked every day ( Ref. 2 Fig. 20A).
Proceed as follows:
- Close the tap Ref. 6 Ref. 20A
- Press the "TEST" button, Ref. 1 Fig. 20A, for a few seconds to check if the condensation is correctly emptied from
the drainage pipe.
- Check manual condensation emptying from the tank, to ensure that condensation is correctly emptied from the valve, Ref. 2 Fig. 20A
(PURGE EVERY DAY AFTER USE).
CLEAN THE DIRT COLLECTOR FILTER (Fig. 20A)
BEFORE CARRYING OUT ANY MAINTENANCE IT IS OBLIGATORY TO STOP THE MACHINE AND DISCONNECT IT
FROM THE POWER MAINS AND FROM THE COMPRESSED AIR DISTRIBUTION NETWORK.
Proceed as follows:
- Switch off the machine with pushbutton Ref. 6 Fig. 20: in this way the machine stops after idle time running.
- Close the cock Ref. 3
- Remove the stopper Rif. 4
- Remove the filter Rif. 5
- Clean the filter Ref. 5 with a jet of air, working from inside to outside.
- Install the filter, fix the plug. Rif. 4 - 5
- Open the cock Rif. 3
.
4 - 5
6
2
Cod. 9828093052 04 - Edition 02/2018 - 33
ENGLISH
FIG. 20A
3
1