20.0 STARTING UP

BEFORE CARRYING OUT ANY OPERATION ON THE MACHINE, ENSURE THAT THE ELECTRIC POWER SUPPLY HAS
BEEN DISCONNECTED.
20.1 PREPARING FOR SETTING UP
After checking everything as indicated in Chap. 12.0, (installation) follow the instructions
20.2 Preliminary checks
Check the oil level Ref. 1 Fig. 24; when delivered the machine is filled with oil; if the oil level is not as intended, top up with the same oil as
the original type. If more than 3 months have passed between the inspection in the factory and the date of installation, lubricate the screw
group before starting up, following the procedure described below:
- Remove the cover Ref. 2 Fig. 24
- Remove the air filter Ref. 3 Fig. 24
- Pour a little oil into the suction unit.
- Reassemble the air filter Ref. 3 Fig. 24
- Reassemble the cover Ref. 2 Fig. 24
If more than 6 months have passed between the inspection in the factory and the date of installation, please contact the service center.
.
1
2
Cod. 9828093052 04 - Edition 02/2018 - 39
OIL
ENGLISH
FIG. 24
3