Variable speed drive compressors
To modify the settings, move the cursor to the action button Modify and press the Enter key.
The first line of the screen is highlighted. Use the Scroll keys to highlight the setting to be modified and press the Enter key. Following
screen appears:
The upper and lower limit of the setting is shown in grey; the actual setting is shown in black. Use the ↑ or ↓ key of the Scroll keys to modify
the settings as required and press the Enter key to accept.
If necessary, change the other settings as required in the same way as described above.
Event history menu
Function: to call up the last shut-down and last emergency stop data.
Procedure: starting from the Main screen (see Main screen), move the cursor to the action button Menu and press the Enter key.
Using the Scroll keys, move the cursor to the Event History icon (see below).
Press the Enter key. The list of last shut-down and emergency stop cases is shown.
Example of Event History screen
Scroll through the items to select the desired shut-down or emergency stop event.
Press the Enter key to find the date, time and other data reflecting the status of the compressor when that shut-down or emergency stop
occurred.
26 - Edition 02/2018 Cod. 9828093052 04 -
(1)
Regolation
(2)
Setpoint 1
(3)
Indirect stop level 1
(4)
Direct stop level 1
(5)
Setpoint 2
(6)
Modify